CDA

Waste Incinerators

The CDA thermometer is intended for measurement of the atmosphere temperature in waste incinerators.It can be used for gas or flame temperature measurement in a variety of other plant situations provided there is sufficient path length.
Its reading is unaffected by cold CO2so it will ‘see through’ a cold combustion atmosphere to measure a hot atmosphere beyond.

Key Benefits

  • The CDA thermometer fits the standard Land System 4 mounting accessories and protection jackets which can be air or water-cooled. The sighting tube should normally be air-purged.
  • The thermometer operates on a simple 2-wire loop connection and outputs a 4 to 20mA signal linear with temperature.
  • The thermometer reading is insensitive to the presence of gasses other than CO2 and is relatively insensitive to particulate matter in the atmosphere – i.e. it measures true gas temperature.
Gallery

It can be used for gas or flame temperature measurement in a variety of other plant situations provided there is sufficient path length. Its reading is unaffected by cold CO2 so it will ‘see through’ a cold combustion atmosphere to measure a hot atmosphere beyond.

In an incinerator it can be pictured as an ‘invisible thermocouple’ extending into the atmosphere above the bed by perhaps 2 metres/6.5 feet (penetration depth depends on atmosphere conditions). In use it is fitted wholly external to the incinerator, usually to a flanged tube penetrating the wall.

Technical Details

Range: 400 to 1800°C
Field of view: 20mm/0.79in parallel to 600mm/23.6in (nominal)
Output: 4 to 20mA linear (2-wire loop connection)
Response time: 1 to 10s adjustable
Emissivity adjustment: 0.10 to 1.00 in 0.01 increments
Resolution: <0.5°C/1°F
Accuracy (absolute): <0.5% Kelvin over 600 to 1600°C/1112 to 2912°F
<1% Kelvin over 400 to 600°C/752 to 1112°F
<1% Kelvin over 1600 to 1800°C/2912 to 3272°F
Ambient temp. limits: 0 to 50°C/32 to 122°F
Drift with ambient temp.: <2° per 10° ambient change
Drift with time: <1°C/2°F per year
Power supply: 11 to 45V d.c.
Sealing: To IP65/NEMA4X requirements
CE: EN 50-082-2 (immunity), EN 50-081-1 (emission), IEC 1010 (safety)
Vibration: 3G, any axis, 10 to 300Hz

Continuous product development may make it necessary to change these details without notice.

Download Datasheet
CDA Incinerator thermometer – datasheet